FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Diethylamine (C4H11N). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Diethylamine is a colorless liquid with an Ammonia-like odor. It is used as a corrosion inhibitor and in making rubber, pharmaceuticals, resins, pesticides and dyes.
Flammable liquids (Category 2), H225 Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 3), H311 Skin corrosion (Category 1A), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Short-term (acute) aquatic hazard (Category 3), H402
Dry Chemical fire suppression is recommended for Diethylamine
Guidance: Dry Chemical fire suppression is generally recommended for Diethylamine (C4H11N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Diethylamine should account for its listed hazards, climate control needs (15 – 25 °C), and segregation requirements. not compatible with STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); CELLULOSE NITRATE; METALS; and CYANIDES.
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: a) Appearance Form: liquid Color: colorless b) Odor ammoniacal c) Odor Threshold No data available d) pH No data available e) Melting point/freezing point Melting point/range: -50 °C (-58 °F) f) Initial boiling point and boiling range 55 °C 131 °F g) Flash point -26 °C (-15 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits Upper explosion limit: 11.8 %(V) Lower explosion limit: 2.0 %(V) k) Vapor pressure 316 hPa at 25 °C (77 °F)
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Diethylamine in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: 15 – 25 °C. Compatibility notes: not compatible with STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); CELLULOSE NITRATE; METALS; and CYANIDES. US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Diethylamine is flagged as a flammable hazard in this database (Yes). Flash point: -26 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Diethylamine is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 2), H225 Acute toxicity, Oral (Category 3), H301 Acute toxicity, Inhalation (Category 4), H332 Acute toxicity, Dermal (Category 3), H311 Skin corrosion (Category 1A), H314 Serious eye damage (Category 1), H318 Specific target organ toxicity - single exposure (Category 3), Respiratory system, H335 Short-term (acute) aquatic hazard (Category 3), H402
Dry Chemical fire suppression is generally recommended for Diethylamine (C4H11N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Diethylamine. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.