Diisopropylamine Chemical Storage Specifications

Compliant storage and rental solutions for Diisopropylamine (C6H15N). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Diisopropylamine

The main commercial applications of diisopropylamine is as a precursor to two herbicides, diallate and triallate, as well as certain sulfenamides used in the vulcanization of rubber. It is also used to prepare N,N-Diisopropylethylamine (Hünig's base) by alkylation with diethyl sulfate.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
-7 C
Storage temperature
15-25 C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE

Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. Flammable Liquids Category 2

Fire Suppression System

Dry Chemical fire suppression is recommended for Diisopropylamine

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Diisopropylamine (C6H15N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Diisopropylamine should account for its listed hazards, climate control needs (15-25 C), and segregation requirements. not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Odor Ammonia-like Odor Threshold No information available pH 12.3 100 g/l water Melting Point/Range -61 °C / -77.8 °F Boiling Point/Range 84 °C / 183.2 °F Flash Point -7 °C / 19.4 °F Evaporation Rate 5.8 (Butyl Acetate = 1.0) Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 7.1% Lower 0.8% Vapor Pressure 95 mbar @ 20 °C Vapor Density 3.5 Specific Gravity 0.716 Solubility Soluble in water Partition coefficient; n-octanol/water No data available Autoignition Temperature 285 °C / 545 °F Decomposition Temperature No information available Viscosity 0.4 mPa.s @ 20 °C Molecular Formula C6 H15 N Molecular Weight 101.19

Matched to this chemical

Recommended storage solutions for Diisopropylamine

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Diisopropylamine be stored?

Store Diisopropylamine in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: 15-25 C. Compatibility notes: not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Diisopropylamine flammable?

Yes — Diisopropylamine is flagged as a flammable hazard in this database (Yes). Flash point: -7 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Diisopropylamine?

Diisopropylamine is listed as: Consult the SDS and applicable hazard classification. Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. Flammable Liquids Category 2

What fire suppression is recommended for Diisopropylamine?

Dry Chemical fire suppression is generally recommended for Diisopropylamine (C6H15N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Diisopropylamine storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Diisopropylamine. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.