
FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Diisopropylamine (C6H15N). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
The main commercial applications of diisopropylamine is as a precursor to two herbicides, diallate and triallate, as well as certain sulfenamides used in the vulcanization of rubber. It is also used to prepare N,N-Diisopropylethylamine (Hünig's base) by alkylation with diethyl sulfate.
Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. Flammable Liquids Category 2
Dry Chemical fire suppression is recommended for Diisopropylamine
Guidance: Dry Chemical fire suppression is generally recommended for Diisopropylamine (C6H15N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Diisopropylamine should account for its listed hazards, climate control needs (15-25 C), and segregation requirements. not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Odor Ammonia-like Odor Threshold No information available pH 12.3 100 g/l water Melting Point/Range -61 °C / -77.8 °F Boiling Point/Range 84 °C / 183.2 °F Flash Point -7 °C / 19.4 °F Evaporation Rate 5.8 (Butyl Acetate = 1.0) Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 7.1% Lower 0.8% Vapor Pressure 95 mbar @ 20 °C Vapor Density 3.5 Specific Gravity 0.716 Solubility Soluble in water Partition coefficient; n-octanol/water No data available Autoignition Temperature 285 °C / 545 °F Decomposition Temperature No information available Viscosity 0.4 mPa.s @ 20 °C Molecular Formula C6 H15 N Molecular Weight 101.19
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Diisopropylamine in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: 15-25 C. Compatibility notes: not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Diisopropylamine is flagged as a flammable hazard in this database (Yes). Flash point: -7 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Diisopropylamine is listed as: Consult the SDS and applicable hazard classification. Acute oral toxicity Category 4 Acute Inhalation Toxicity - Vapors Category 3 Skin Corrosion/Irritation Category 1 B Serious Eye Damage/Eye Irritation Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system. Flammable Liquids Category 2
Dry Chemical fire suppression is generally recommended for Diisopropylamine (C6H15N). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Diisopropylamine. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.