Dinitrotoluene Chemical Storage Specifications

Compliant storage and rental solutions for Dinitrotoluene (C7H6N2O4). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Non-flammableNon-Flammable Storage

Chemical formula

About Dinitrotoluene

Dinitrotoluene is an orange-yellow, crystalline (sand-like) solid that is often shipped in a molten state. It is used in making polyurethanes, explosives, dyes and other chemicals.

Structured hazard data

Hazard class
Muta. 2 H341 Suspected of causing genetic defects. Carc. 1B H350 May cause cancer. Repr. 2 H361 Suspected of damaging fertility or the unborn child. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.
Storage category
Non-Flammable Storage
Flammable
No
Flash point
155 °C (311 °F)
Storage temperature
<150 C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
incompatible with strong oxidizing agents, caustics, active metals, tin and zinc

Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H311 Toxic in contact with skin. Acute Tox. 3 H331 Toxic if inhaled.

Fire Suppression System

Dry Chemical fire suppression is recommended for Dinitrotoluene

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Dinitrotoluene (C7H6N2O4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2 or water spray. LARGE FIRE: Water spray, fog or regular foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Dinitrotoluene should account for its listed hazards (Muta. 2 H341 Suspected of causing genetic defects. Carc. 1B H350 May cause cancer. Repr. 2 H361 Suspected of damaging fertility or the unborn child. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.), climate control needs (<150 C), and segregation requirements. incompatible with strong oxidizing agents, caustics, active metals, tin and zinc

Review Segregated storage for incompatible chemicals and How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.

Properties: · Change in condition Melting point/Melting range: 69.6 °C (157.3 °F) Boiling point/Boiling range: 300 °C (572 °F) · Flash point: 155 °C (311 °F) · Flammability (solid, gaseous): Product is not flammable. · Ignition temperature: 420 °C (788 °F) · Decomposition temperature: Not determined. · Auto igniting: Not determined. · Danger of explosion: Product does not present an explosion hazard. · Explosion limits: Lower: Not determined. Upper: Not determined. · Vapor pressure at 50 °C (122 °F): 0.1 hPa (0.1 mm Hg) · Density at 20 °C (68 °F): 1.521 g/cm³ (12.69275 lbs/gal)

Matched to this chemical

Recommended storage solutions for Dinitrotoluene

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Non-fire-rated0 HourChemical Storage Shipping

    BoxSAFE CX

    • Non Fire-Rated
    • 8 ft x 40 ft x 8' 5"
    • 50 Qty 55 Gallon Drums
    • 9 Pallets or Totes
    • 302 Square Feet storage
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rated

    • 0-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rate

    • 0-Hour Fire-Rated
    • 8 ft x 20 ft
    • 27 Barrels
    • 55 Gal Storage Drums
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Dinitrotoluene be stored?

Store Dinitrotoluene in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Muta. 2 H341 Suspected of causing genetic defects. Carc. 1B H350 May cause cancer. Repr. 2 H361 Suspected of damaging fertility or the unborn child. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.). Climate range guidance: <150 C. Compatibility notes: incompatible with strong oxidizing agents, caustics, active metals, tin and zinc US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Dinitrotoluene flammable?

Dinitrotoluene is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.

What hazard class is Dinitrotoluene?

Dinitrotoluene is listed as: Muta. 2 H341 Suspected of causing genetic defects. Carc. 1B H350 May cause cancer. Repr. 2 H361 Suspected of damaging fertility or the unborn child. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.. Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H311 Toxic in contact with skin. Acute Tox. 3 H331 Toxic if inhaled.

What fire suppression is recommended for Dinitrotoluene?

Dry Chemical fire suppression is generally recommended for Dinitrotoluene (C7H6N2O4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Dinitrotoluene storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Dinitrotoluene. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.