Kerosene Chemical Storage Specifications

Compliant storage and rental solutions for Kerosene (C12H26C15H32). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Kerosene

Cooking, lighting, and heating are the main household services provided by kerosene, although there are kerosene refrigerators and other appliances in some areas. Kerosene heating is not widespread in temperate or highland areas of developing countries, mainly because of cost.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
100.4 – 125.6 ˚F (38 -52 ˚C)
Storage temperature
>-40 F
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
will react with nitric acid, hydrogen peroxide, and strong oxidizers with evolution of heat and may ignite. Such mixtures of kerosine and oxidizers are likely to be sensitive to shock, heat, and sparks.

Flam. Liquid Category 3 H226 Skin Corrosion/Irritation Category 2 H315 Aspiration Hazard Category 1 H304 STOT SE Category 3 H336 Aquatic Chronic Category 2 H411

Fire Suppression System

Dry Chemical fire suppression is recommended for Kerosene

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Kerosene (C12H26C15H32). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Foam, carbon dioxide, dry chemical are most suitable

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Kerosene should account for its listed hazards, climate control needs (>-40 F), and segregation requirements. will react with nitric acid, hydrogen peroxide, and strong oxidizers with evolution of heat and may ignite. Such mixtures of kerosine and oxidizers are likely to be sensitive to shock, heat, and sparks.

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Melting Point -4 ˚F (-20 ˚C) Boiling Point Range 300 to 580 ˚F (149 to 304 ˚C) Flash Point 100.4 – 125.6 ˚F (38 -52 ˚C) Evaporation Rate Slow, varies with conditions Flammability Flammable liquid Flammable Limits 0.7 % - 5.0% Vapor Pressure 0.480 mm Hg @ 20 ˚C Vapor Density 4.5

Matched to this chemical

Recommended storage solutions for Kerosene

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Kerosene be stored?

Store Kerosene in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: >-40 F. Compatibility notes: will react with nitric acid, hydrogen peroxide, and strong oxidizers with evolution of heat and may ignite. Such mixtures of kerosine and oxidizers are likely to be sensitive to shock, heat, and sparks. US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Kerosene flammable?

Yes — Kerosene is flagged as a flammable hazard in this database (Yes). Flash point: 100.4 – 125.6 ˚F (38 -52 ˚C). Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Kerosene?

Kerosene is listed as: Consult the SDS and applicable hazard classification. Flam. Liquid Category 3 H226 Skin Corrosion/Irritation Category 2 H315 Aspiration Hazard Category 1 H304 STOT SE Category 3 H336 Aquatic Chronic Category 2 H411

What fire suppression is recommended for Kerosene?

Dry Chemical fire suppression is generally recommended for Kerosene (C12H26C15H32). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Kerosene storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Kerosene. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.